Références
*George, A., Khalil,A., Hassan, H. Comparison between cylinder and tapered implants in delayed immediate placement. Alexandria Dental Journal, 2015; 40(2): 221-228.
** Norton MR, Astrom M. Int J Oral Maxillofac Implants 2020; 35:1099-1111.
Caractéristiques de l’Astra Tech Implant System EV (Soft Tissue Chamber, MicroThread, Conical Seal Design, OsseoSpeed :
1. Barewal RM, Stanford C, Weesner TC. A randomized controlled clinical trial comparing the effects of three loading protocols on dental implant stability. Int J Oral Maxillofac Implants 2012;27(4):945-56.
2. De Bruyn H, Raes F, Cooper LF, et al. Three-years clinical outcome of immediate provisionalization of single Osseospeed implants in extraction sockets and healed ridges. Clin Oral Implants Res 2013;24(2):217-23.
3. Galindo-Moreno P, Nilsson P, King P, et al. Clinical and radiographic evaluation of early loaded narrow diameter implants - 1-year follow-up. Clin Oral Implants Res 2012;23(5):609-16.
4. Noelken R, Donati M, Fiorellini J, et al. Soft and hard tissue alterations around implants placed in an alveolar ridge with a sloped configuration. Clin Oral Implants Res 2014;25(1):3-9.
5. Noelken R, Neffe BA, Kunkel M, Wagner W. Maintenance of marginal bone support and soft tissue esthetics at immediately provisionalized Osseospeed implants placed into extraction sites: 2-year results. Clin Oral Implants Res 2014;25(2):214-20.
Soft Tissue Chamber :
6. Abrahamsson I and Berglundh T. Tissue Characteristics at Microthreaded Implants: An Experimental Study in Dogs. Clin Impl Dent Rel Res 2006;8(3):107-13.
7. Palmer RM, et al. Astra Tech single-tooth implants: an audit of patient satisfaction and soft tissue form. J Clin Periodontol 2007;34(7):633-8.
8. Moon IS, et al. The Barrier Between the Keratinized Mucosa and the Dental Implant. An Experimental Study in the Dog. J Clin Periodontol 1999;26:658-63.
9. Mertens C, Steveling HG. Early and immediate loading of titanium implants with fluoridemodified surfaces: results of 5-year prospective study. Clin Oral Implants Res. 2011 Dec;22(12):1354-60
MicroThread :
10. Lee DW, Choi YS, Park KH, Kim CS, Moon IS. Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study. Clin Oral Implants Res 2007;18(4):465-70.
11. Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants:An experimental study in dogs. Clin Implant Dent Relat Res 2006;8(3):107-13.
12. Hansson S, Werke M. The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study.J Biomech 2003;36(9):1247-58.
Conical Seal Design :
13. Hansson S. A conical implant-abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone. An axisymmetric finite element analysis.Clin Oral Implants Res 2003;14(3):286-93.
14. Zipprich H, Weigl P, Lauer H-C, et al. Micro-movements at the implant-abutment interface: measurements, causes and consequenses. Implantologie 2007; 15:31-45.
15. HarderS, Dimaczek B, Acil Y, Terheyden H, Freitag-Wolf S, Kern M. Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration.Clin Oral Investig 2010;14(4):427-32.
16. Toia M, Galli S, Cecchinato D, et al. Clinical Evidence of OsseoSpeed EV Implants: A Retrospective Study and Characterization of the Newly Introduced System.Int J Periodontics Restorative Dent 2019;39(6):863-74.
OsseoSpeed :
17. Ellingsen JE, Johansson CB, Wennerberg A, Holmén A. Improved retention and bone-to-implant contact with fluoride-modified titanium implants. Int J Oral Maxillofac Implants 2004;19(5):659-66.
18. Berglundh T, Abrahamsson I, Albouy JP, Lindhe J. Bone healing at implants with a fluoride-modified surface: an experimental study in dogs. Clin Oral Implants Res 2007;18(2):147-52.
19. Geckili O, Bilhan H, Bilgin T. A 24-week prospective study comparing the stability of titanium dioxide grit-blasted dental implants with and without fluoride treatment. Int J Oral Maxillofac Implants 2009;24(4):684-88.
20. Barewal RM, Stanford C, Weesner TC. A randomized controlled clinical trial comparing the effects of three loading protocols on dental implant stability.
21. Int J Oral Maxillofac Implants. 2012;27(4):945-956.